DocumentMT0100P.N
©XsensTechnologiesB.V. MTiandMTxUserManualandTechnicalDocumentation
22
MTi or MTx coordinate frame before (A) and after (B) object reset. The new Zaxis of the sensor coordinate
framewillbealongthevertical.ThenewdirectionoftheX axiswillbetheoldX–axisthatisprojectedon the
horizontalplane.
4.6.5 Alignmentreset
ThealignmentresetsimplycombinestheObjectresetandtheHeadingresetatasingleinstantintime.This
hastheadvantagethatallcoordinatesystemscanbealignedwithasingleaction.Keepinmindthatthenew
globalreferencexaxis(heading)isdefinedbytheobjectXaxis(towhichXZplaneyouhavealignedtheMTi/
MTx).
NOTE:Oncethisalignmentresetisconducted,bothcalibrateddataandorientationwillbeoutputwithrespect
tothenewScoordinateframe.
4.7 Timestampoutput
Timestampoutputcanbeenabledordisabled(usingtheSetOutputSettings message).Thetimestamp
isalwayslastinthedatafieldoftheMTDatamessage.
Currently, there is one option for the timestamp output, the sample counter which is a 16 bit counter
increasingwith1witheachMTDatamessagesent.Afterreaching(2^16)‐1=65535thesamplecounterwill
wraptozero(0).
4.8 TestandCalibrationCertificate
EachMTiandMTxisaccompaniedbyanindividualTestandCalibrationCertificate.Thiscertificatestatesthe
calibration values determined during the calibration of the MTi and MTx in Xsens’ calibration facilities. The
valuesareexplainedhereinshort:
TheSpecifications
chaptercontainsthefullrangesandbandwidthsofthephysicalsensorsinside.
TheBasictestresults
describesthenoiseofthe3sensortypesanditcontainsresidualsinorientation.
Noise Thenoiseontheindividualsensorsignals
16
.
Staticaccuracyresidual Theresidualcalibrationerrorforstaticorientationsatroomtemperature
Temperatureresidual The residual calibration error for static orientations over the temperature
range
Calibration data
are the values that describe the conversion from the physical phenomenon to a digital
outputinanorthogonalcoordinatesystem:
Gains(bits):Gains(orscalefactor)describetherelationbetweenthedigitalreadinginbitsandthemeasured
physicalsignal.
Offsets(bits):Digitalreadinginbitsofthesensornophysicalsignalismeasured.
Alignmentmatrix:Nonorthogonalityofthesensortriade.Thisincludesnonorthogonalityintheorientation

16
Theresolutionofthesensorsignalsarealwayslimitedbythenoiseinthesensorsignal,notbytheaccuracy
or resolution of the analog to digial converter. Exceptions are the temperature and static pressure sensor
wherequantizationcanbesignificant.
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 64 65

Comentarios a estos manuales

Sin comentarios

Atlas SRC22JC podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Zamrażarki Atlas SRC22JC.
Dostarczamy 2 pdf podręczników Atlas SRC22JC do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Zamrażarki Atlas

Modele Rodzaj dokumentu
SKB1622 Instrukcja Użytkownika Atlas SKB1622 Brugermanual [de] , 16 strony
KC2450 Instrukcja Użytkownika Atlas KC2450 Brugermanual, 16 strony
SKC1610 Instrukcja Użytkownika Atlas SKC2100 Brugermanual [de] [es] [fr] [nl] , 16 strony
KC4000 Instrukcja Użytkownika Atlas KC4000 Brugermanual [en] , 12 strony
BS18092 Instrukcja Użytkownika Atlas BS18092 Brugermanual, 12 strony
BN1109 Instrukcja Użytkownika Atlas BN1109 Brugermanual, 8 strony
KC4000 Instrukcja Użytkownika Atlas KC4000 Brugermanual [ua] , 12 strony
BS25092 Instrukcja Użytkownika Atlas BS25092 Brugermanual, 12 strony
KC2110 Instrukcja Użytkownika Atlas KC2110 Brugermanual [fr] , 16 strony
SKC2500 Instrukcja Użytkownika Atlas SKC2500 Brugermanual [pl] , 16 strony
SKF2705 Instrukcja Użytkownika Atlas SKF2705 Brugermanual [fr] , 20 strony
BL3609 Instrukcja Użytkownika Atlas BL3609 Användarmanual, 12 strony